PRODUCTS


    IDA8 Full Redundancy Unit > BATTERY CHARGERS


    Ancillary Audio Switcher

    Product Number: RU-PDC


    The IDA8 RU switching redundancy units provide the high level of redundancy and acting as a Primary/Secondary switching device for IDA8C controller and IDA8SAB slave unit. RU-PDC device is a device supplied with full-redundancy for audio processor.

    The RU-PDC provides 2 monitored PDC-ports for paging remote devices, 1 set of telephone line and 8 configurable audio I/O for the Primary IDA8C controller and the Secondary IDA8C controller.

    The RU-PDC is in charge of switching the primary IDA8C and the secondary IDA8C processor and is also capable to monitor the status of processor. If the primary processor breaks down, the RU-PDC will automatically detect and all signal including from the peripherals will switch to the secondary processor.


    Read More Order Inquiry


    Description

    RU-PDC
    Switching unit with audio in/out contacts, paging console & telephone line interface

    The IDA8 RU switching redundancy units provide the high level of redundancy and acting as a Primary/Secondary switching device for IDA8C controller and IDA8SAB slave unit. RU-PDC device is a device supplied with full-redundancy for audio processor.

     

     

     

    The RU-PDC provides 2 monitored PDC-ports for paging remote devices, 1 set of telephone line and 8 configurable audio I/O for the Primary IDA8C controller and the Secondary IDA8C controller.

    The RU-PDC is in charge of switching the primary IDA8C and the secondary IDA8C processor and is also capable to monitor the status of processor. If the primary processor breaks down, the RU-PDC will automatically detect and all signal including from the peripherals will switch to the secondary processor.

     

    Note – In cooperation with RU devices for redundancy purpose, please refer to our local sales for:
     * External DC power calculation for IDA8S
     * Special order for IDA8C, IDA8C-SW, IDA8SAB and IDA8SAB-SW

    Specifications

    Eletrical

    • 24 VDC power supply
      • Voltage: 24VDC
      • Power comsumption: 350 mA

    Interconnections

    • 8 x 0 dB inputs or outputs , 2 PSS inputs, 2 tel inputs
    • Switching: electrical mechanical relays
    • Switching time: 6 seconds (IDA8 watchdog period)
    • Connections: RJ45, screw terminals blocks
    • LED display: power, primary IDA8 system active, secondary IDA8 system active
    • Control inputs: primary IDA8 system watchdog, secondary IDA8 system watchdog
    • Control outputs: Primary IDA8 system active, secondary IDA8 system active, expansion

    Mechanical

    • Dimensions (W x H x D): 436 x 44 x 150 mm (17.2 x 1.7 x 5.9 inch)
    • Weight: 2.5 kg (5.5 lbs)
    • Mounting: 19″ 1U rack
    • Colour: RAL 7016

    Environmental

    • Operating temperature: -5 ºC ~ +55 ºC (+23 ºF ~ +131 ºF)
    • Storage temperature: -40 ºC ~ +70 ºC (-40 ºF ~ +158 ºF)
    • Relative humidity: 20 % to 95 %
    • Air pressure: 600 to 1100 hPa
    • Heat dissipation: 28 BUT/hr

    Applications

    Full Redundancy Application


     

     

    Partial Redundancy Application

    Contact Us

    ATEÏS Middle East – Dubai (HQ)

     

    LIU-1 No.10 & 11 Dubai Silicon Oasis P.O. Box 293640 Dubai U.A.E
    T: +971 (4) 3262730 F: +971 (4) 3262731
    E: info@ateis.ae  –  Linkedin  –  TwitterYoutube

     

    ATEÏS Middle East – India

     

    4th Floor, 411, V Times Square,  Sector 15, CBD Belapur,
    Navi Mumbai – 400 614.
    Tel:- +91 22 4968 7447